Polyethylene wear knee
WebUltra-high-molecular-weight polyethylene (UHMWPE, UHMW) ... available commercially either as fibers or in consolidated form, such as sheets or rods. Because of its resistance to wear and ... was first used clinically in 1962 by Sir John Charnley and emerged as the dominant bearing material for total hip and knee replacements in ... WebAug 17, 2015 · Official Title: Polyethylene Wear Study on the Triathlon Total Knee Prosthesis A Prospective Randomized Single Centre Roentgen Stereophotogrammetric Analysis …
Polyethylene wear knee
Did you know?
WebJun 1, 2004 · 1.. IntroductionInvestigation into the survival of knee replacements has implicated polyethylene wear as a cause of failure. Not only does the function of the … Websion cycles of the knee make more demands on the polyethylene in the knee than on the hip (Bartel et al. 1986). Even if the majority of the patients have good clinical results we …
WebNational Center for Biotechnology Information WebMar 1, 2002 · The factors that may affect high molecular weight polyethylene wear in TKA include: contact area, level and kind of joint surface stresses, polyethylene properties …
WebDec 30, 2024 · ITPIE is a reliable treatment for instability and/or polyethylene wear after TKA in the presence of well-fixed and well-aligned components with good survival and clinical … Webmium alloy causes less wear than a titanium-alloy sur- face in tests simulating the clinical situation with third body wear or runaway wear (McKellop 1991, Milliano and Whiteside …
WebSep 15, 2024 · TKA Polyethylene Wear refers to macroscopic premature failure of polyethylene (PE) due to excessive loading and mechanical loosening. Diagnosis is …
WebA posterior cruciate-retaining total knee arthroplasty design (PFC, Deputy Johnson & Johnson, Warsaw, IN) was selected for testing. Inserts were 8 mm thick and were made … crystal vibration frequencyWebApr 20, 2015 · The TiN-coating has a positive effect on the biocompatibility and tribological properties of implant surfaces; however, there are several reports of third body wear due to delamination, increased ultrahigh molecular weight polyethylene wear, and cohesive failure of the TiN-coating. This might be due to the coating process. crystal vibration chartWebAbstract. Initial design cementless metal-backed patellar implants failed due to multiple reasons including implant design, use of first-generation polyethylene, and surgical … dynamic offset cancellation techniquesWebMay 16, 2024 · In wear tests that use a linear motion path, such as a reciprocating pin on disc, the rate of polyethylene wear for a given set of test conditions is 10 to 100 times … crystal vibrational therapyWebUltra-high-molecular-weight polyethylene (UHMWPE, UHMW) is a subset of the thermoplastic polyethylene.Also known as high-modulus polyethylene, (HMPE), it has … dynamic offset cancellationdynamic offsetWebNov 29, 2009 · Revision knee and patella arthroplasty was carried out after a thorough debridement of the knee joint. Long-term follow-up is critical for patients with total joint replacement for early detection of occult polyethylene wear and prosthesis loosening. In these cases, revision arthroplasty may provide a satisfactory knee function. dynamic office and accounting solutions